Common Issues: ​Troubleshooting Coleman Mach air conditioners

7th Feb 2024

Troubleshooting Coleman Mach air conditioners can help RV owners diagnose and address common issues they may encounter while on the road. Here are some detailed troubleshooting tips to help you identify and resolve problems with your Coleman Mach air conditioner:

1. Insufficient Cooling:

  • Check Air Filter: A dirty or clogged air filter can restrict airflow and reduce cooling efficiency. Remove the air filter and clean or replace it if necessary.
  • Inspect Coils: Check the evaporator and condenser coils for dirt or debris buildup. Clean the coils using a soft brush or compressed air to improve heat transfer and cooling efficiency.
  • Verify Temperature Setting: Ensure that the thermostat is set to the desired temperature and mode (cooling mode). Adjust the temperature setting if needed.

2. No Airflow:

  • Inspect Fan Motor: Check the fan motor for signs of damage or obstruction. Ensure that the fan blades spin freely and are not obstructed by debris.
  • Check Fan Speed: Verify that the fan speed setting is appropriate for the cooling needs. Adjust the fan speed if necessary.
  • Clear Air Vents: Ensure that the air vents are not blocked by furniture, curtains, or other obstructions. Clear any blockages to allow for proper airflow.

3. Unit Not Turning On:

  • Check Power Supply: Verify that the RV is receiving power from the shore power or generator. Check the circuit breaker or fuse box for any tripped breakers or blown fuses.
  • Inspect Thermostat: Ensure that the thermostat is set to the "On" or "Cool" mode and the temperature setting is lower than the current room temperature.
  • Verify Wiring Connections: Inspect the wiring connections at the air conditioner unit and thermostat. Tighten any loose connections and ensure proper electrical continuity.

4. Unit Cycling On and Off Frequently:

  • Check Airflow: Verify that the air filter and coils are clean and free of obstructions. Poor airflow can cause the unit to cycle on and off frequently.
  • Inspect Refrigerant Levels: Low refrigerant levels can cause the system to cycle on and off excessively. Consult a professional technician to check for leaks and recharge the refrigerant if necessary.
  • Verify Thermostat Placement: Ensure that the thermostat is not exposed to direct sunlight, drafts, or heat sources, as this can cause inaccurate temperature readings and cycling.

5. Unusual Noises:

  • Inspect Fan Blades: Check the fan blades for signs of damage or debris. Clean the blades and ensure they are securely fastened to the motor shaft.
  • Inspect Compressor: Listen for any unusual noises coming from the compressor. Grinding or rattling noises may indicate a problem with the compressor motor or internal components.
  • Check Mounting: Verify that the air conditioner unit is securely mounted to the RV roof. Loose or damaged mounting hardware can cause vibrations and noise during operation.

6. Water Leakage:

  • Clear Condensate Drain: Check the condensate drain line for blockages or clogs. Clear any debris or buildup to allow proper drainage of condensate water.
  • Inspect Seals: Check the seals around the air conditioner unit for signs of damage or deterioration. Replace any damaged seals to prevent water leakage.
  • Verify Installation: Ensure that the air conditioner unit is installed correctly and level on the RV roof. Improper installation can cause water to pool and leak into the interior of the RV.

7. Electrical Issues:

  • Check Power Supply: Verify that the RV is receiving adequate power from the shore power or generator. Test the voltage at the air conditioner unit to ensure it meets the manufacturer's specifications.
  • Inspect Wiring: Inspect the wiring connections for signs of damage, corrosion, or loose connections. Repair or replace any damaged wiring as needed.
  • Test Capacitor: Use a multimeter to test the capacitance of the start and run capacitors. Replace any capacitors that are out of spec or show signs of damage.

8. Ice Buildup on Coils:

  • Check Airflow: Insufficient airflow can cause the evaporator coils to freeze. Ensure that the air filter and vents are clean and unobstructed.
  • Verify Refrigerant Levels: Low refrigerant levels can also cause ice buildup on the coils. Consult a professional technician to check for leaks and recharge the refrigerant if necessary.
  • Thaw Coils: Turn off the air conditioner and allow the coils to thaw completely before restarting the unit. Use a fan or gentle heat source to expedite the thawing process if needed.

9. Remote Control Malfunction (if applicable):

  • Check Batteries: Replace the batteries in the remote control if it is not responding or functioning erratically.
  • Reset Remote Control: Reset the remote control by removing the batteries and pressing any button for 5 seconds. Reinsert the batteries and test the remote control.
  • Verify Signal Reception: Ensure that there are no obstructions between the remote control and the air conditioner unit. Aim the remote control directly at the unit and try again.

10. Professional Assistance:

If troubleshooting steps do not resolve the issue, or if you are uncomfortable performing DIY repairs, it is advisable to seek professional assistance from certified technicians familiar with Coleman Mach air conditioners. They can diagnose the problem accurately and perform the necessary repairs or maintenance to ensure the optimal performance of your air conditioning system.